Peer Revenue Publish or profit

Papers

Fresh from arXiv, typeset properly. Highlighted words trade on the market.

Physics Physics Medical Physics

physics.med-ph Watch Medical Physics (sign in to use)

Tuesday 22 September

Medical Physics

Towards Modeling the Hemodynamic Impact of Mitral and Aortic Valve Repair in Patients with Left Ventricular Assist Devices

Valve dysfunction is a major threat to long-term success in left ventricle assist device (LVAD) therapy, with direct implications for right heart performance. In this study, we apply a patient-specific, image-based computational modeling framework to evaluate the hemodynamic impact of simulated mitral and aortic valve repair in five LVAD-supported patients. Each patient was modeled under four conditions: (patient-specific LVAD-supported state), simulated mitral valve (MV) repair, simulated aortic valve (AV) repair, and simulated combined MV&AV repair. Because validation data for valve repair were unavailable, the simulated repair scenarios are exploratory in silico interventions based on clinically validated patient-specific models. The models integrate dynamic CT imaging, echocardiography, catheterization data, and device-specific LVAD parameters into a coupled 3D-0D simulation pipeline. Valve dynamics are governed by transvalvular pressure and flow, allowing physiological modeling of regurgitant lesions and surgical repair. The right ventricular (RV) was assessed using a combination of model-derived metrics, including right ventricular ejection fraction (RVEF), pulmonary artery pulsatility index (PAPi), and RV-PA coupling. In addition, we performed blood residence time (RT) analysis to evaluate blood stasis within the left heart and aorta. The simulations suggest that valve repair improved cardiac output, reduced pulmonary congestion, and enhanced right ventricular loading conditions. Notably, mitral valve repair restored aortic valve opening during the cardiac cycle, which improved sinus washout and reduced blood residence time within the aortic root-factors associated with lower thrombotic risk. Overall, these findings suggest a potential role for valve repair in LVAD-supported hearts, though larger, validated patient cohorts are needed to confirm these results.
Read the full abstract

All authors Mia Bonini, Michael Ferguson, Marc Hirshvogel, Maximilian Balmus, Paul C. Tang, Francis Pagani, David Nordsletten

Medical Physics · Cross-listed from cond-mat.soft

Experimental Characterization of the Passive Mechanical Behavior of Rat Pelvic Floor Muscles: Effects of Test Conditions and Pregnancy

Purpose: Pelvic floor muscles undergo large deformations during vaginal delivery, yet the passive tensile behavior of pregnant and non-pregnant pelvic floor muscle and the influence of testing protocols remain incompletely characterized. This study evaluated how pregnancy, loading rate, preconditioning, and storage affect passive tensile mechanics of rat pelvic floor muscle. Methods: Levator ani samples from pregnant and non-pregnant rats were tested in uniaxial tension to failure across multiple preconditioning amplitudes, two loading rates, and fresh or frozen storage conditions. Peak and transition metrics, strain energy density, toe-region stiffness, and high-strain stiffness were extracted using automated region-detection methods. Rat properties were also compared with digitized human cadaver levator ani data. Results: Pregnant rat samples reached greater peak strains than controls, although the difference was not significant. Preconditioning affected peak strain in a loading-rate-dependent manner: responses tapered near 2% preconditioning strain at 0.5% strain/s, whereas no comparable tapering occurred through 15% at 1% strain/s. Compared with human cadaver data, rat samples reached substantially larger peak strains and lower high-strain stiffness. Conclusion: This study provides one of the first direct experimental comparisons of passive pelvic floor muscle mechanics between pregnant and non-pregnant tissue, while systematically evaluating how multiple testing-protocol variables influence the measured response. Distinguishing protocol-dependent variability from biological differences provides a more reproducible basis for cross-study comparison and constitutive model calibration. Rat pelvic floor muscle is a useful model for pregnancy-associated adaptation, but absolute mechanical values should be translated to human tissue cautiously.
Read the full abstract

All authors Jose L. Monclova, Matthew Shankel, Ava M. English, Mona Eskandari, Heidi P. Feigenbaum

Medical Physics

4D Pencil Beam Treatment Plan with Conditional Weight Predictions

Objective. This work aims to accelerate our four-dimensional (4D) proton pencil beam delivery strategy, which incorporates respiratory motion into a dynamic treatment plan, to improve dose conformity and treatment efficiency for gantry-less and magnet-free scanner designs. Approach. To accelerate the generation and adaptation of 4D treatment plans, we propose a conditional hybrid ResNet18-Transformer model for predicting pencil beam weights. The model predicts either the full set of pencil beam weights or a subset thereof. Main Results. The conditional model can successfully predict the remaining beam weights of a treatment, and the results suggest that extending this approach to full treatment prediction is feasible but requires further investigation. Significance. The acceleration of 4D treatment generation via pencil beam weight prediction takes us one step closer to the feasibility of treating mobile targets with simplified, gantry-less, and magnet-free scanner designs. Reducing system complexity while preserving dosimetric conformity may offer a pathway toward more accessible and cost-effective proton beam therapy for motion-affected tumours. Our code is available here: https://github.com/NairVonMuehlenen/Pencil-Beam-Weight-Prediction
Read the full abstract

Medical Physics

Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons

Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an experimental investigation of a hybrid Prompt-Gamma Imaging (PGI)–Positron-Emission Tomography (PET) concept at the isochronous cyclotron of the West German Proton Therapy Centre under clinically representative pencil-beam-scanning conditions. Because this accelerator delivers a quasi-continuous beam, a pulsed shoot-and-step structure was imposed to mimic the interruptions associated with clinical energy-layer switching. This enabled PGI during irradiation and PET and delayed Compton imaging during beam-off intervals within the same sequence. Four two-plane Compton cameras were arranged in a co-planar cross-shaped geometry around the beam isocenter. Polyethylene phantoms were irradiated with 100~MeV protons at known positions along the beam axis. Their positions were estimated from reconstructed one-dimensional profiles using supervised machine-learning models trained exclusively on Monte Carlo simulations. PET achieved the best performance, with a root-mean-square deviation of 0.8~mm, followed by PGI with 1.6~mm. Delayed Compton imaging based on e$^{+}$ annihilation photons and $^{10}$C$^{*}$ decays yielded 2.4~mm and 3.8~mm, respectively. PET retained good performance down to 1% of the original event statistics, whereas PGI became increasingly statistics-limited. These results demonstrate the complementary strengths of hybrid PGI–PET and support its development towards millimetre-scale proton-range verification under clinically relevant irradiation conditions.
Read the full abstract

All authors Javier Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco, P. Torres-Sánchez, I. Ladarescu, M. Pallàs, B. Brusasco, J. Wulff, C. Bäumer, A. Tarifeño-Saldivia, C. Domingo-Pardo

Medical Physics

A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systems

Purpose: To develop a wearable, stretchable radio-frequency (RF) coil that conforms to the extremities and improves the filling factor in low-field MRI. Methods: A stretchable solenoid RF coil was fabricated by stitching a sinusoidally arranged Litz-wire conductor onto an elastic textile. The coil was compared with four rigid coils, including two routinely used designs and two prototypes designed to isolate the effects of conductor material and stretchability. Performance was characterized through quality-factor, loading-factor, transmit-efficiency, and image-based signal-to-noise ratio (SNR) measurements. Phantom and in-vivo knee experiments for one volunteer were performed using two portable MRI systems operating at 3.53 and 3.04 MHz. Results: The electrical performance of the selected Litz wire decreased with increasing frequency, becoming a slight disadvantage at 3.53 MHz. Nevertheless, the stretchable coil provided the highest phantom SNR in both systems, exceeding that of the best-performing rigid coil by approximately 8 % at 3.53 MHz and 20 % at 3.04 MHz. In vivo, its global SNR was 5 % lower than that of the best rigid coil at 3.53 MHz and 19 % higher at 3.04 MHz. Compared with the larger rigid coil required when knee positioning is constrained, the corresponding SNR improvements were approximately 18 % and 80 %. Conclusion: Anatomical conformity can compensate for the frequency-dependent electrical limitations of Litz wire in stretchable low-field RF coils. The proposed design provided SNR comparable to or greater than the best rigid designs while facilitating coil placement in subjects for whom smaller rigid coils may be impractical.
Read the full abstract

All authors Jesús Conejero, Marina Fernández-García, José Borreguero, Teresa Guallart-Naval, Pablo García-Cristóbal, Lorena Vega-Cid, Eli G. Castañón, Rubén Bosch, Eduardo Pallás, Pablo Moreno, Fernando Galve, Joseba Alonso, José Miguel Algarín

Monday 21 September

Medical Physics · Cross-listed from physics.flu-dyn

Silk-templated Nanostrips as Superprotonic Fibre Sensors

Transforming textile fibres into sensors can facilitate continuous physiological monitoring for improving human healthcare. Coating fibres with electronic conductors can help detect physiological stimuli but their sensitivity scales with thickness and often lowers the fibre mechanical flexibility. Proton conductors are potential alternatives; however, they suffer from fragile physical interfaces, and sluggish kinetics. Here, we report a bio-templated, scalable strategy to create superprotonic interfaces using natural silk fibres. We exploit ordered nanofibrils on silk fibres to selectively grow continuous metal-organic framework (MOF) nanostrips. This patterned, ca. $10\,\mu\mathrm{m}$-diameter fibre-structure provides low-defect interfacial pathways for ultrafast proton transport, yielding conductivities up to 40 $S\,cm^{-1}$ - two orders of magnitude above the state of the art - with millisecond response and high mechanical robustness. The individual micro-thread sensors facilitate respiratory monitoring with a mean bias of 0.01 breaths $min^{-1}$ in volunteer testing, unaffected by human movement and readily capture breathing signature in high-flow oxygen therapy devices. We integrate arrays of micro-thread sensors in textiles and exploit deep learning to demonstrate high-resolution spatiotemporal humidity mapping in dynamic flow-fields and resolve asymmetric respiratory patterns that elude conventional single-point detectors. Our results should have broad-ranging implications, e.g. in wearable health monitoring, bioelectronics, and human-machine interfaces.
Read the full abstract

All authors Jianhui Zhang, Ahmed Salem, Robert Tidswell, Haowei Wang, Vikramjeet Singh, Laurence B. Lovat, Manish K. Tiwari

Medical Physics

Towards Sustainable Magnetic Resonance Imaging: Insights from long-term, high-resolution energy recordings across an entire scanner fleet

Magnetic resonance imaging (MRI) is among the most energy-intensive diagnostic modalities in healthcare, yet its energy consumption and the factors influencing it remain insufficiently understood. This study aims to establish a comprehensive baseline of MRI energy consumption by characterizing energy demand across a scanner fleet, examining scanner utilization and operating patterns in clinical practice. Concurrently, it investigates the relationships between energy consumption and relevant operational and acquisition features. On average, a single MRI measurement consumed 0.43 kWh, while a complete examination consumed 13.50 kWh. In general, substantial differences in energy consumption were observed between MRI scanners and their corresponding operating modes (scan, idle, and eco-power mode). These variations may be related to differences in scanner operating patterns, employed examination protocols, and their resulting acquisition parameters. Idle and eco-power modes accounted for more cumulative energy consumption than active scanning. However, these energy shares should always be interpreted in relation to scanner occupancy, as utilization patterns strongly influence the distribution of energy across those operating modes. Lastly, linear regression analysis showed that energy consumption was more strongly associated with scan duration than with average power, suggesting that scan duration may be an important factor influencing MRI energy consumption. ...
Read the full abstract

All authors Florian Leonhard Raab, Fiona Mankertz, Nour Maalouf, Josephine Berger, Andreas Lingg, Reza Dehdab, Sebastian Werner, Judith Herrmann, Andreas Brendlin, Sebastian Gassenmaier, Suhas Siddaramu, Fabian Wagner, Julian Wohlers, Shreeja Varadarajan, Gurlal Singh, Jens Gühring, Rainer Schneider, Konstantin Nikolaou, Saif Afat, Thomas Küstner

Medical Physics

Clinical Commissioning of the First Ultra-Compact Gantry-less Upright Proton Therapy System

This study reports the comprehensive clinical commissioning and benchmarking of a novel ultra-compact, gantry-free, upright PT system.
Read the full abstract

All authors Serdar Charyyev, Adam Johansson, Zhuoran Jiang, Veng Jean Heng, Cynthia Fu-Yu Chuang, Melanie R Piantino, Samuel Graham, Lawrie B Skinner, Nataliya Kovalchuk, Vivek Maradia, Xianjin Dai, Xuejun Gu, Bin Han, Lloyd Emmanuel Kamole Ghomsi, Susan M Hiniker, Yuan James Rao, Billy W Loo Jr, Lei Xing, Murat Surucu, Yong Yang

Medical Physics · Cross-listed from q-bio.PE

Stochastic Field Theory of HIV Latency: Instanton Dynamics and the Path to Viral Rebound

The transition from clinical latency to active HIV infection is a stochastic process. Traditional deterministic models based on ordinary differential equations (ODEs) fail to capture the extinction boundary and the subsequent rebound of the virus because they neglect demographic noise in the small-population limit. We map the resulting Master Equation onto a coherent-state path integral using the Doi-Peliti second-quantization formalism and verify that the stochastic Hamiltonian reproduces the correct mean-field ODEs on the classical manifold $\bar{\phi}_i = 1$. In the semiclassical (large system-size) limit we derive eight coupled Hamilton-Jacobi equations, identify the virus-free and endemic fixed points, and obtain the basic reproduction number $R_0$ for the four-species network. For the analytically tractable case of single-virion bursting ($n=1$) we show that the stochastic Hamiltonian factorizes into two bilinear terms, exposing a non-trivial zero-energy surface that constitutes the instanton trajectory. A quasi-steady-state reduction then yields a first-order linear ODE whose closed-form solution gives the instanton action $S_{\rm inst}$ in terms of biological parameters. Calibrating to clinical data—infected-cell half-life $\delta_I^{-1}\approx 2\,\rm d$, viral burst size $N\approx 10^3$, clearance rate $\delta_V\approx 23\,\rm d^{-1}$, reactivation rate $\eta\approx 10^{-3}\,\rm d^{-1}$, and latent reservoir size $L_0\approx 10^6$ cells—we obtain a mean first-passage time (MFPT) to viral rebound of $\approx 6$ months for a typical patient, with a range of days to years depending on reservoir size. These predictions are qualitatively consistent with observed post-interruption rebound timescales.
Read the full abstract

Medical Physics

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.
Read the full abstract

All authors Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang

Sunday 20 September

Medical Physics · Cross-listed from eess.IV

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.
Read the full abstract

All authors Omer Burak Demirel, Kelly K. Horst, Alessio Perazzolo, Elisa Bruno, Kenan Kaya, Rongzhen Ouyang, Enas Ahmed, Jouke Smink, Spencer L. Waddle, Zainudeen Kallumpurath, Tzu Cheng Chao, Dinghui Wang, Steve G. Langer, Timothy L. Kline, Panagiotis Korfiatis, Jacinta Browne, Ivana Isgum, Tim Leiner

Medical Physics

Buccal-Lingual Analysis and Inflammation Tracking in Oral Soft Tissues Using Quantitative Ultrasound: A Preclinical Study

Four out of 10 adults aged 30 years or older in the USA are impacted by periodontal diseases which span a spectrum of inflammatory conditions. Currently, a subjective, invasive and a semi-quantitative approach, termed bleeding on probing, is employed in clinics for inflammation assessment. The long-term goal of this study is to fill the current clinical diagnostic gap in dentistry by proposing quantitative ultrasound (QUS)-based biomarkers for inflammation diagnosis and monitoring. Here, as one of the early works in this area, we investigated two QUS parameters for characterizing periodontal inflammation in gingival tissues using a longitudinal preclinical porcine study: attenuation coefficient slope (ACS) and backscatter intensity (BSI). Our study included eight pigs imaged intraorally (24 MHz) at four bi-weekly timepoints from week 0 (healthy) to week 6 (post inflammation inoculation) at their interproximal sites of the third premolars (PM3-Mes) from all quadrants. Moreover, we compared gingival tissues surrounding a tooth at lingual/palatal side versus buccal side at the second molar (M2-Dis) in healthy condition. Our results showed that gingival ACS at all inflammation timepoints were significantly lower than healthy gingival ACS (1.69 \pm 0.53 dB/cm.MHz) using a mixed effect analysis (week 6: 1.08 \pm 0.25 dB/cm.MHz). Longitudinal comparison of BSI did not demonstrate any statistical significance. Gingival ACS and BSI at lingual/palatal versus buccal sides of M2-Dis did not exhibit any statistical significance. These ACSs were linearly correlated with R-squared = 0.89 and a correlation slope of 0.87. For BSI, Bland-Altman analysis demonstrated no difference in mean BSI, although variability was high. These findings highlight the promising potential of ultrasonography paired with QUS to complement current standard of care in dentistry.
Read the full abstract

All authors Daria Poul, Amanda Rodriguez Betancourt, Ankita Samal, Carole Quesada, Ted Lynch, Cristel Baiu, J. Brian Fowlkes, Hsun-Liang Chan, Oliver D. Kripfgans

Saturday 19 September

Medical Physics

Free-Breathing PDFF and R2* Quantification at 0.55T: Reduced Respiratory Motion Sensitivity and a Time-Resolved 4D MRI Approach

Purpose: Free-breathing multi-echo MRI enables hepatic PDFF/R2* quantification without breath-holds, but respiratory motion can affect R2* estimation through motion-induced field variations. We investigated whether respiratory motion sensitivity is reduced at 0.55T versus 3T and developed a time-resolved free-breathing 4D MRI approach without respiratory binning. Methods: A navigator-embedded multi-echo stack-of-stars sequence was implemented. Ten subjects were scanned during free breathing and deliberate bulk motion at both 3T and 0.55T. Data were reconstructed using motion-averaged, motion-resolved, and time-resolved approaches. Quantitative performance was also evaluated in a PDFF/R2* phantom using Cartesian and radial acquisitions. Results: Phantom experiments showed close radial-Cartesian agreement for R2* and PDFF at 3T. At 0.55T, R2* showed good agreement over the low-to-moderate range but higher uncertainty at high R2*, where larger radial-Cartesian PDFF differences were also observed. R2* was substantially less sensitive to respiratory motion at 0.55T than at 3T, whereas PDFF was relatively insensitive at both field strengths. Under bulk motion, time-resolved reconstruction provided robust R2* and PDFF measurements, with particularly high consistency between free-breathing and bulk-motion acquisitions at 0.55T. Conclusion: R2* quantification was less sensitive to respiratory motion at 0.55T than at 3T, while PDFF remained relatively insensitive. Time-resolved reconstruction provided additional robustness to bulk motion. Reduced susceptibility effects at 0.55T and time-resolved reconstruction may provide complementary advantages for motion-robust free-breathing hepatic R2* and PDFF quantification.
Read the full abstract

All authors Jeffery Wong, Jingjia Chen, Ding Xia, Xiang Xu, Els Fieremans, Dmitry S. Novikov, Hersh Chandarana, Li Feng

Medical Physics · Cross-listed from eess.SP

Complementary-Aperture Pulse Sequencing for Fundamental-Band Nonlinearity Parameter Imaging

The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation because of the slightly nonlinear scaling between excitation voltage set on the ultrasound system and pressure at the probe. We propose a complementary-aperture pulse sequence (CAPS) that recovers the linearly scaled low-pressure signal by coherently summing RF acquisitions from interleaved transmit subapertures whereas a full-aperture transmission provides the high-pressure signal maintaining the same excitation voltage configured in the ultrasound system. In silico phantoms of a homogeneous sample and a reference evaluated four aperture partitions of CAPS and compared them with the DM under relative scaling-factor errors from 0.01% to 10%. Using the DM, errors of 0.1% and 1% produced absolute B/A biases of up to 27.3% and 58.3%, respectively. CAPS yielded mean B/A values of 8.9 for a prescribed value of 9, with biases of less than 1.3% across all partitions, matching an ideally calibrated DM. These results demonstrate that CAPS preserves depletion-based B/A estimation without using the pressure scaling factor as a reconstruction input, supporting experimental and in vivo implementation without pressure-ratio calibration.
Read the full abstract

All authors Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila

Medical Physics · Cross-listed from eess.IV

Signal recovery in the polychromatic computed tomography model: Injectivity and complexity

We consider a nonlinear model motivated by polychromatic computed tomography (CT). Here, $W$ distinct $d$-dimensional signals $x^*_1, \ldots, x^*_W \in \mathbb{R}^d$ must be recovered from $n$ measurements $(a_i, y_i)_{i = 1}^n$ that obey the nonlinear model $\mathbb{E}[y_i|a_i] = h(\langle a_i, x^*_1 \rangle, \ldots, \langle a_i, x^*_W \rangle)$, where $h: \mathbb{R}^W \to \mathbb{R}$ is a known nonlinearity that models a certain type of exponential attenuation law. Even when there is no noise in the measurements, the sample size $n$ (for any measurement ensemble $\{a_i\}_{i = 1}^n$) must exceed the number of unknowns $Wd$ to guarantee that the underlying signals are identifiable. We construct a measurement ensemble that ensures perfect signal recovery almost surely provided $n \geq Wd + W - 1$, thereby isolating the injectivity threshold up to an additive factor $W - 1$. We also study computational complexity of signal recovery in this model with a general measurement ensemble $\{a_i\}$. We show that if $W \geq 2$, then there is a measurement ensemble for which deciding whether there exist signals consistent with the measurements is NP-hard. In particular, this implies that polychromatic, multimaterial CT reconstruction is NP-hard in general. This finding stands in sharp contrast to the single-material setting, for which a polynomial-time algorithm can provably perform signal recovery for any measurement ensemble.
Read the full abstract

Friday 18 September

Medical Physics · Cross-listed from math.OC

Parallel Optimization: Theory, Algorithms, and Applications,

This 30 years old book is posted for free download by the generosity of Oxford University Press that granted permission to allow access to future generations of young scientists. A printed copy can be purchased from the publisher. The authors received for this book "The 1999 INFORMS Computing Society Prize for Research Excellence in the Interface Between Operations Research and Computer Science" from the Institute for Operations Research and the Management Sciences (INFORMS). For a book review by Janos D. Pinter go to: Journal of Global Optimization, 16: 107-108, 2000.
Read the full abstract

Medical Physics

Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.
Read the full abstract

Thursday 17 September

Medical Physics

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.
Read the full abstract

Medical Physics

Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell Microscopy

Induced pluripotent stem cell (iPSC) culture increasingly relies on segmentation foundation models, yet deployment on laboratory CPUs and edge hardware requires compression schemes that are both efficient and auditable. We present a deployment-oriented evaluation of compressed Cellpose-SAM using a pre-specified retention criterion: the 95% cluster-bootstrap interval of mean change from FP32 must remain above a fixed -0.02 margin for every imaging modality. On a stratified 176-field panel spanning BBBC038 nuclei, BBBC039 U2OS fluorescence, and NIST iPSC images across density regimes, weight-only W8A16 preserves instance F1 across all modalities. A sensitivity-guided mixed W4/W8 scheme, using four INT8 exceptions, achieves a 6.76x reduction in weight storage with no observed catastrophic failures (0/176 fields), matching W8A16 at this sample size. In contrast, ternary weight-only quantization achieves 12.08x compression but fails catastrophically on 169/176 fields. These results demonstrate that compression should be evaluated by modality-stratified downstream retention rather than single-number accuracy, and establish a reproducible protocol for auditing compressed foundation models in regulated stem-cell imaging.
Read the full abstract

Medical Physics

T2 estimation from MOLLI acquisitions

Cardiac T1 and T2 quantitative magnetic resonance imaging (MRI) is a technique that provides characterization of a multitude of myocardial pathologies. However, each parameter requires its own specialized acquisition sequence, which may be time-consuming. In this work, we demonstrate that MOLLI, an acquisition sequence commonly used to perform T1 mapping, is also sensitive to T2, and can also be used for myocardial T2 mapping. Although MOLLI is not designed for T2 mapping, its signal evolution inherently depends on both T1 and T2 relaxation. Here, we demonstrate that this dependence is sufficiently strong to allow T2 estimation directly from MOLLI T1-weighted images, using appropriate signal modelling. This finding opens the possibility of obtaining simultaneously T1 and T2 maps from a single MOLLI acquisition, reducing total scan time and potentially improving patient comfort and clinical throughput.
Read the full abstract

All authors Catarina N Carvalho, Andreia S Gaspar, Rita G Nunes, Teresa M Correia

Wednesday 16 September

Medical Physics

Retinal hazards and glare from space mirrors

Projects of orbital mirrors reflecting sunlight towards Earth raise reasonable concerns regarding photochemical and thermal retinal hazards and detrimental effects on visual performance (disability glare). This paper addresses these issues based on some current eye safety and glare standards. Telescopic observations of single mirrors appear to pose a significant risk of photochemical retinal hazard. The risk is higher for vulnerable populations. Unaided eye viewing of a mirror keeps the retinal risks low, both photochemical and thermal; however, disability glare may be unacceptably high, affecting awareness and response in critical visual operations. The simultaneous presence of several mirrors in the visual field of the observer, seen with the unaided eye or through optical instruments, will significantly increase all types of hazards. The kind and severity of their combined effects will depend on the angular distance between them. Additional information is needed to evaluate the effects of the transient flashes of light during mirror slewing operations.
Read the full abstract

Medical Physics · Cross-listed from eess.SP

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).
Read the full abstract

All authors Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila

Medical Physics · Cross-listed from cs.CV

Video-Based Markerless Motion Capture for Clinical and Rehabilitation Biomechanics: A PRISMA-ScR Scoping Review of Validated Architectures, Clinical Readiness, and Emerging Methods

Background.. Video-based markerless motion capture promises movement analysis without the cost, space and skin-marker constraints of optoelectronic systems, with particular potential for clinical and rehabilitation settings. Whether validated pipelines yet deliver clinically acceptable biomechanics, and how they relate to the underlying computer-vision research, remains unclear. Methods. We conducted a scoping review following the PRISMA extension for Scoping Reviews, with a registered protocol and searches of PubMed, Scopus and IEEE Xplore (January 2015 to February 2026; the computer-vision scan was updated to July 2026). A dual-tier design paired a primary corpus of validated biomechanical studies with a complementary, curated and deliberately non-exhaustive corpus of emerging computer-vision work, used qualitatively. We charted study characteristics, pipeline architecture, validation methods and joint-angle accuracy. Results. We included 117 studies, most published from 2024 onward and conducted on healthy adults walking in a laboratory. Pipelines formed five architectural families across monocular and multi-camera modalities; most reported raw joint angles without biomechanical refinement. Sagittal lower-limb agreement clustered around 5 to 6{\textdegree}, generally short of clinical acceptability, while out-of-plane kinematics, kinetics, and pathological or older populations were rarely validated. Emerging computer-vision building blocks (foundation-model mesh recovery, differentiable inverse kinematics, video-based kinetics) were almost absent from validated studies. Conclusions. Video-based markerless capture is not yet interchangeable with marker-based systems for clinical joint kinematics, and it remains barely validated where rehabilitation needs it most: older and pathological populations, out-of-plane kinematics, and kinetics. Mapping this evidence gap onto emerging computer-vision advances, we propose hypothesis-generating design guidelines, not a validated method, to steer the next generation of pipelines toward accessible, clinically meaningful movement analysis.
Read the full abstract

All authors Florian Delaplace, Elodie Piche, Frédéric Chorin, Raphael Zory

Medical Physics · Cross-listed from physics.optics

On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron

Several propagation-based and analyser-based X-ray phase-contrast imaging experiments with over 100 m between the imaged objects and the detector were carried out at the Imaging and Medical beamline (IMBL) of the Australian Synchrotron. These experiments were aimed at characterization of possible phase-contrast imaging setups at IMBL. Effects of the beam divergence, polychromaticity and X-ray source size on the contrast and spatial resolution of images were evaluated quantitatively in different imaging scenarios. The results of this work will be used for improving the existing and developing new imaging capabilities at the beamline. Applications to X-ray phase-contrast tomography of biomedical samples, particularly for medical breast cancer imaging, are briefly discussed.
Read the full abstract

All authors T.E. Gureyev, K.M. Pavlov, C.J. Hall, A. Maksimenko, D. Pelliccia, D.M. Paganin, A.W. Stevenson, A. Entezam, H.M. Quiney

Tuesday 15 September

Medical Physics · Cross-listed from q-bio.OT

Flash-Radiomics: A Scalable Hybrid CPU-CUDA Engine for Standardized Scalar Radiomics and Accelerated Spatial Mapping

Background and Objectives: Spatial mapping retains the spatial distribution of radiomic features, but computational cost and fragmented software limit its use. We developed Flash-Radiomics with scalar extraction and spatial mapping, a central processing unit (CPU) backend, a hybrid Compute Unified Device Architecture (CUDA) backend, consistent feature names, and Hierarchical Data Format version 5 (HDF5) storage. Methods: We evaluated Image Biomarker Standardisation Initiative (IBSI) compliance, CPU-CUDA concordance, and end-to-end processing time. Compliance testing included 825 chapter 1 (IBSI-1) tests covering 165 high-consensus features and 323 chapter 2 (IBSI-2) tests with numerical references. Concordance testing included 1,148 scalar pairs and 93 spatial-map pairs. End-to-end processing time was measured five times per input volume of interest (VOI) size. Comparisons included the Medical Image Radiomics Processor (MIRP) and PyRadiomics for 102 shared scalar features and PyRadiomics for 93 shared spatial maps. Results: Both backends passed all 1,148 IBSI tests, and all paired results were concordant. At the largest scalar input, CPU required 76.343 s and hybrid CUDA 81.915 s; CPU was 4.7 times faster than MIRP and 190.7 times faster than PyRadiomics. At the largest spatial input completed by both backends, hybrid CUDA reduced processing time by 68.6% relative to CPU (79.280 versus 252.791 s). At PyRadiomics' largest completed spatial input, hybrid CUDA was 84.9 times faster. Conclusions: Flash-Radiomics unified standardized scalar extraction, spatial mapping, concordant CPU-CUDA results, and HDF5 storage. CPU processing time was similar or shorter for scalar extraction, whereas hybrid CUDA was faster for spatial mapping under the tested conditions.
Read the full abstract

All authors Shanli Ding, Yiyi Hu, Ziyu Fu, Chia-Hsin Lin, Ruihan Luo, Jaehee Chun, Xinyue Zhang, Osama Mawlawi

Medical Physics

The Magnetic-Resonance-Based, Omni-Directional Hydrophone

This study aims to improve the directional sensitivity of magnetic resonance hydrophone (MRH) methods and allow for detection and quantification of waves traveling at any angle relative to the MRI bore-axis. Doing so may better integrate MRH technology into transcranial focused ultrasound neuromodulation therapies. Existing MRH implementations only encode acoustic waves propagating along the MRI bore-axis, precluding use with wide aperture transducers or temporal skull windows. This study expands the MRH technique into a MR-based Omni-directional Hydrophone (MRbOH) that can quantify the magnitude pressure and phase of waves propagating at any angle. The MRbOH method formulates a system of equations around uniquely sensitized images that, when solved, introduce sensitivity to oblique acoustic waves. The method was tested experimentally in a gel phantom that was insonated at $0^o$, $45^o$, and $90^o$ relative to the MRI bore-axis. The method reconstructed pressure maps at all three angles of propagation, including features such as peak pressure, partial reflections, and beamwidth. The MRbOH method measured an average beamwidth of 16.2 mm while the hydrophone measured a beamwidth of 14.5 mm. Average hydrophone-measured pressure within a region of interest was 416.19 $\boldsymbol{\pm}$ 78.07 kPa. Average MRbOH measured pressure in the same region at $0^o$, $45^o$, and $90^o$, respectively, were: 285.5 $\boldsymbol{\pm}$ 49.5 kPa, 193.13 $\boldsymbol{\pm}$ 43.55 kPa, 194.7 $\boldsymbol{\pm}$ 47.38 kPa. In addition, the study presents and experimentally verifies a statistical noise model that predicted the mean with $R^2 = 0.85$, and standard deviation with $R^2 = 0.83$.
Read the full abstract

All authors Nathan Thyberg, Davi Cavinatto, Katia Oler, Elijah Oxborrow, Hyrum Mangum, Steven P. Allen

Medical Physics · Cross-listed from physics.flu-dyn

Comparative Evaluation of Carotid Artery Hemodynamics: Patient-Specific CFD Simulations vs. 4D flow MRI

Wall shear stress (WSS) is implicated in carotid atherosclerosis, and 4D flow MRI offers a non-invasive route to its estimation, but the agreement of MRI-derived plaque-surface WSS with computational fluid dynamics (CFD) has not been quantified in a large cohort. We compared peak-systolic velocity and WSS from 4D flow MRI and patient-specific CFD in 240 carotid arteries of 120 patients, with CFD geometries and boundary conditions derived from MRI. Velocity and circumferential WSS were compared at three standardized cross-sections, and plaque-surface WSS in 63 of 149 stenosed arteries with a reliably segmented plaque. Agreement was assessed with Bland-Altman analysis, Spearman correlation with stenosis degree, and exploratory multivariable regression of the plaque-surface discrepancy on hemodynamic and geometric variables. MRI reproduced the broad flow features but underestimated peak velocity, increasingly toward the distal internal carotid artery. WSS disagreement was location dependent: mean circumferential WSS showed little average bias in the common carotid artery, whereas MRI missed the high WSS at the bifurcation apex and underestimated plaque-surface mean and maximum WSS by $40.9 \pm 28.8\%$ and $44.5 \pm 26.8\%$; the difference in Pa increased with stenosis degree ($\rho = 0.47$ and $0.50$). In exploratory regression, the CFD-derived pressure drop across the plaque was the only significant correlate of the mean WSS discrepancy, whereas stenosis degree and geometric variables were associated with the maximum WSS discrepancy. Under the present protocol, MRI-derived plaque-surface WSS showed magnitude- and location-dependent disagreement with CFD, greater in more severely stenosed arteries and, in exploratory analyses, associated with factors beyond stenosis degree.
Read the full abstract

All authors Ali Mokhtari, Merel Meulendijks, Ariel Bergmann, Christoph Strecker, Jonathan Andrae, Andreas Harloff, Dominik Obrist

Medical Physics

Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators

Purpose: To characterise and harmonise multileaf collimator (MLC) gap calibrations across four beam-matched TrueBeams and assess a common planning-system model. Methods: Four Millennium 120 TrueBeams were studied: TS1 (installed 2016), TS5 (2021), TS6 and TS7 (2024). Gap calibration was assessed by RayStation sweeping-gap measurement, feeler gauge, the EPID-based Stakitt Fence test, and a leaf-resolved Machine Performance Check (MPC). TS1 and TS5 were adjusted in service mode, TS5 also for MLC centreline offset. Ten clinical VMAT plans, and six acquired earlier on an unadjusted reference machine, were measured with an ArcCHECK 1220 against doses computed at 0.053 and 0.065 cm x-offsets in RayStation. Results: The 2024 machines had wider baseline gaps. All four methods registered the TS1 and TS5 changes in the same direction and within 0.060 mm of predictions. After adjustment TS1 and TS5 lay within the TS6/TS7 sweeping-gap and Stakitt ranges but read wider on the feeler gauge. A conventional picket-fence test on TS5 registered no change. Raising the RayStation x-offset parameter increased mean local 3%/2 mm pass rates from 92.3% to 94.8% on TS1 and 93.2% to 95.6% on TS5; all 24 plan-criterion pairs improved on the unadjusted machine. Conclusions: Mechanical, EPID, and sweeping gap MLC gap measurements responded consistently to the MLC adjustment, moving TS1 and TS5 towards the local reference range. Every global 3%/2 mm ArcCHECK measurement exceeded the TG-218 95% limit.
Read the full abstract

All authors Michael Douglass, Corey Bridger, Mitchell Herrick, Joshua Southwell, Andrew Kennedy, Michael Barnes, Joerg Lehmann

Monday 14 September

Medical Physics

Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators

Beam monitoring detectors play an important role in experimental control and radiological protection by enabling the real-time characterization of particle and photon beams. They provide information on beam intensity, position, and scattering, helping to ensure measurement accuracy, protect sensitive detectors, and quantify stray radiation in the surrounding environment. In this work, a Geant4 simulation was developed to investigate the performance of an X-ray beam monitoring detector (BMD) composed of six hexagonal BC404 plastic scintillators arranged to provide high granularity, using a reflector with a realistic reflectivity of 93%. Under the simulation conditions considered in this study, the detector exhibited an intrinsic time resolution of 100.8 $\pm$ 2.0~ps. The results indicated that only about 10% of the incident photons interacted with the detector, suggesting that the proposed design could be used for beam characterization while minimally perturbing the primary beam. In addition, the X-ray multiplicity decreased with distance according to an inverse-square dependence. A backscatter study performed using a water phantom showed that approximately 6% of the incident beam was detected as scattered radiation. These results suggest that the proposed detector may be a useful tool for X-ray beam characterization and for studies related to scatter radiation and radiological protection. Further experimental validation is required to confirm these findings.
Read the full abstract

All authors C. H. Zepeda Fernández, E. Moreno Barbosa, J. M. Arredondo-Velázquez, L. F. Rebolledo-Herrera

Sunday 13 September

Medical Physics · Cross-listed from cs.CV

From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced Mammography

Purpose: To compare four multimodal large language models (MLLMs) with radiologists of varying expertise in breast density assessment, BI-RADS assessment, biopsy candidacy determination, and continuous malignancy probability estimation using digital mammography (DM) and contrast-enhanced mammography (CEM). Methods: This study included 179 women with paired DM/CEM examinations and reference standards. Four MLLMs (ChatGPT-5.2, Gemini-3.1 Pro, Sonnet-4.6, Muse Spark) interpreted images with and without masks; three radiologists interpreted non-masked images. Results: For binary density classification on DM, radiologist accuracies ranged from 55.81% to 78.60%, exceeding most MLLM values (62.33%-71.63%), while masks added limited benefit. Five-category BI-RADS accuracies were higher for radiologists on DM (56.74-67.44%) and CEM (62.33-82.79%) compared with MLLMs (DM 31.16-45.12%; CEM 40.00-55.81%). Binary biopsy-candidacy accuracies were likewise higher for radiologists (DM 85.12-89.77%; CEM 86.98-92.09%) than for MLLMs (DM 61.39-75.35%; CEM 69.30-82.79%), although CEM improved performance across all readers. Lesion masks substantially improved MLLM continuous malignancy-probability accuracies from 64.65%-71.63% to 72.56-78.60% on DM and from 67.91%-77.21% to 72.56%-81.86% on CEM, approaching radiologist ranges (DM 63.72-82.79%; CEM 81.86-88.84%). The corresponding AUCs for the top masked models overlapped those of the human readers. Overall, Muse Spark, followed by Sonnet-4.6, demonstrated the strongest performance among the MLLMs across domains. Conclusion: Radiologists generally outperformed MLLMs in categorical tasks, while selected masked models approached human performance for continuous malignancy probability estimation, suggesting a potential adjunctive role.
Read the full abstract

All authors Ali Abbasian Ardakani, Afshin Mohammadi, Taha Yusuf Kuzan, Beyza Nur Kuzan, Alisa Mohebbi, Masume Behruzi, Hamid Khorshidi, Ashkan Ghorbani, Elham Asadiara, Zeinab Khorshidi Lotfi, Ansar Rahman, Nedim Christoph Beste, U. Rajendra Acharya, Sepideh Hatamikia